Y-Axis Parameters
/
Fast Closing Advanced

Fast Closing Advanced

Hem Bend Cycle

Y-Axis parameters - Fast closing advanced - Hem bend cycle

Method

Range

Normal

Default

Normal/Fast

Units

NA

Access

Administrator

Function

Description

Speed below 10.0 mm/s

Y-Axis parameters - Fast closing advanced - Speed below

P-gain

Range

0.1-99.9

Default

1

Units

NA

Access

Administrator

Function

To set proportional gain factor for the Y-axis during fast closing in case the speed is set to 10 mm/s or lower and obtain desired response to changes in the control signal.

Description

NA

Feed forward friction value

Range

0-999.9

Default

0

Units

NA

Access

Service

Function

To set gain factor for the Y-axis when approaching the programmed position in case the speed is set to 10 mm/s or lower and obtain a quick and smooth approach to mute point.

Description

NA

Contents

  • Hem Bend Cycle
  • Method
  • Speed below 10.0 mm/s
  • P-gain
  • Feed forward friction value
Fast Closing Pressing

      Copyright © 2023 by Metamation. All rights reserved.

    Compiled by Bento